Gree Split AC Error Codes
Gree split inverter AC units show error codes on the indoor unit display when a fault is detected. Find your code below for a full explanation and fix guide.
Error Codes
b5
Gree
Split AC
b5 means the outdoor refrigerant pipe temperature sensor has a fault or failed …
b7
Gree
Split AC
b7 means the crankcase heater (or outdoor pipe heater) has a fault or is not …
C5
Gree
Split AC
C5 means the jumper cap on the indoor control board is missing, wrong, or …
E1
Gree
Split AC
E1 means the refrigerant pressure inside the system has exceeded safe limits. …
E2
Gree
Split AC
E2 means the indoor evaporator coil is getting dangerously cold and is about to …
E4
Gree
Split AC
E4 means the hot gas leaving the compressor is above safe temperature limits. …
E5
Gree
Split AC
E5 means the AC is drawing more electrical current than is safe.
The system …
E6
Gree
Split AC
E6 means the indoor and outdoor units have lost communication with each other. …
EU
Gree
Split AC
EU means the four-way valve area temperature has hit its limit and the system …
F2
Gree
Split AC
F2 means the outdoor air temperature sensor has an open or short circuit. …
F3
Gree
Split AC
F3 means the temperature sensor on the outdoor condenser coil has a fault.
This …
F4
Gree
Split AC
F4 means the sensor monitoring the outdoor discharge pipe temperature has a …
F5
Gree
Split AC
F5 means the exhaust (discharge) temperature sensor has an open or short …
F6
Gree
Split AC
F6 means the system has detected overheating and automatically slowed down the …
F8
Gree
Split AC
F8 means the AC has detected excess current draw and reduced the compressor …
F9
Gree
Split AC
F9 means the compressor is drawing dangerously high current and protection has …
FC
Gree
Split AC
FC means both the compressor and the outdoor fan motor have malfunctioned …
FE
Gree
Split AC
FE is not a fault — it means the AC is running a normal defrost cycle on the …
H0
Gree
Split AC
H0 means the compressor failed to start within the allowed time after receiving …
H1
Gree
Split AC
H1 is not a fault — it means the AC is running its automatic defrost or …
H2
Gree
Split AC
H2 is not a fault — it means the AC is running its electrostatic dust removal …
H3
Gree
Split AC
H3 means the compressor is drawing excessive current and its internal overload …
H4
Gree
Split AC
H4 means both the indoor and outdoor coils are in an overload protection state …
H5
Gree
Split AC
H5 means the Intelligent Power Module — the inverter component that drives the …
H6
Gree
Split AC
H6 means the outdoor condenser fan is not spinning or is running incorrectly. …
H7
Gree
Split AC
H7 means the inverter compressor has lost synchronisation and cannot maintain …
HE
Gree
Split AC
The HE code means the indoor unit's EEPROM memory chip has a fault.
The chip …
L3
Gree
Split AC
L3 means the outdoor unit's DC fan motor is not running or not spinning fast …
LC
Gree
Split AC
LC means the compressor tried to start but failed after multiple attempts.
This …
LD
Gree
Split AC
LD is a critical error — the compressor is receiving incomplete or unbalanced …
LE
Gree
Split AC
LE is a critical error — the compressor drew a dangerous current spike far above …
P5
Gree
Split AC
P5 means the compressor current exceeded the safe limit measured by the outdoor …
P6
Gree
Split AC
P6 means the indoor main board and the outdoor inverter drive board cannot …
P7
Gree
Split AC
P7 means the IPM (Intelligent Power Module) sensor circuit has a fault.
The IPM …
P8
Gree
Split AC
P8 means the PFC (Power Factor Correction) circuit in the outdoor unit has …
PC
Gree
Split AC
PC means either the indoor control panel (display board) has a circuit fault, or …
PH
Gree
Split AC
PH means the DC voltage inside the outdoor inverter circuit is too high.
This …
PL
Gree
Split AC
PL means the DC voltage inside the outdoor inverter circuit is too low to run …
PU
Gree
Split AC
PU means the startup charge circuit for the main inverter capacitor is not …
U1
Gree
Split AC
U1 means the inverter drive detected that the compressor rotor is losing its …
U2
Gree
Split AC
U2 means the system detected that the compressor wiring phase order is reversed. …
U3
Gree
Split AC
U3 means the voltage inside the IPM (Intelligent Power Module) is too high for …
U4
Gree
Split AC
U4 means the system detected the compressor spinning in reverse during …
U5
Gree
Split AC
U5 means the circuit that measures AC current on the outdoor PCB is not working …
U7
Gree
Split AC
U7 means the four-way valve (which switches between cooling and heating mode) …
U8
Gree
Split AC
U8 means the sensor monitoring the exhaust temperature at the compressor …