F1
Lloyd Split AC
Severity: ModerateWhat Does This Error Mean?
F1 on a Lloyd AC means the indoor ambient temperature sensor (room thermistor) has a fault. This sensor reads room temperature so the AC knows when to increase or reduce cooling to maintain the set temperature. F1 triggers a safety shutdown — without reliable room temperature data, the AC cannot operate correctly.
Affected Models
- Lloyd Inverter Split AC (all capacities)
- Lloyd 3 Star Inverter
- Lloyd 5 Star Inverter
- Lloyd GLS series
- Lloyd LS series Inverter
Common Causes
- Indoor ambient thermistor failed — resistance outside the normal range
- Thermistor connector loose at the indoor PCB
- Thermistor wire damaged during installation or annual AC service
- Dust accumulation on the thermistor probe
- Indoor PCB fault causing incorrect reading of the ambient sensor
How to Fix It
-
Switch off at the remote and main switch. Wait 5 minutes and restart.
If F1 clears and does not return, it was a transient error. Monitor over the next few uses.
-
Clean the indoor unit air filter.
A blocked filter affects airflow over the ambient sensor and can contribute to abnormal readings.
-
Call Lloyd service (1800-315-1111) if F1 persists.
Note your model number and purchase date when calling — required for warranty claims.
When to Call a Professional
F1 requires a Lloyd (Havells) authorised technician. Lloyd customer care: 1800-315-1111. A technician will test the ambient thermistor and replace it if it reads outside specification.
Frequently Asked Questions
Lloyd is now part of Havells — does that affect warranty?
Lloyd ACs are now manufactured and serviced by Havells India. Warranty claims and service bookings go through Havells — call 1800-315-1111. Your existing Lloyd warranty remains valid and is honoured by Havells.