10123, 10124

Anycubic 3D Printer

Severity: Moderate

What it means

Anycubic's error code list for its FDM printers (Kobra 3, Kobra S1, Kobra X and others) has two temperature sensor codes; NTC is the temperature sensor.
CODE 10123: Hotbed NTC abnormal.
CODE 10124: Extruder NTC abnormal; the printer cannot read a valid nozzle temperature, and it stops heating.
Anycubic says not to restart again and again or force a print before the fault is found, because the nozzle temperature could get out of control.

How to Fix It

  1. Turn the printer off and unplug it before checking any cables.

    Let the hotbed and hotend cool down first.

  2. For 10124, remove the print head housing and replug the print head NTC cable, making sure it is fully seated.

    Then gently pull the print head connection cable; if it is loose, tighten its two screws with a 1.5 mm hex key.

  3. Remove the bottom plate and replug the print head cable at the mainboard.

    For 10123, replug the hotbed T1 cable at the mainboard instead.

  4. For 10123, check the temperature on the main screen with the printer cold.

    It is normally around 25 °C, close to the room temperature.
    Anycubic says this code also shows when the reading is below 10 °C; move the printer somewhere warmer.

  5. If it still shows, measure the sensor's resistance at room temperature with the printer off.

    This needs some electrical knowledge and a multimeter; skip it if you are not comfortable with that.
    Anycubic's values at 25 °C: about 100 kΩ, within 15 kΩ for the print head and 10 kΩ for the hotbed.
    Outside that range, Anycubic says to replace the print head or the hotbed.

  6. If the code stays, contact the store you bought the printer from or Anycubic's technical support.

    Anycubic asks for a photo of the error code, the model and serial number, and the firmware version.