10123, 10124
Anycubic 3D Printer
Severity: ModerateWhat it means
Anycubic's error code list for its FDM printers (Kobra 3, Kobra S1, Kobra X and others) has two temperature sensor codes; NTC is the temperature sensor.
CODE 10123: Hotbed NTC abnormal.
CODE 10124: Extruder NTC abnormal; the printer cannot read a valid nozzle temperature, and it stops heating.
Anycubic says not to restart again and again or force a print before the fault is found, because the nozzle temperature could get out of control.
How to Fix It
-
Turn the printer off and unplug it before checking any cables.
Let the hotbed and hotend cool down first.
-
For 10124, remove the print head housing and replug the print head NTC cable, making sure it is fully seated.
Then gently pull the print head connection cable; if it is loose, tighten its two screws with a 1.5 mm hex key.
-
Remove the bottom plate and replug the print head cable at the mainboard.
For 10123, replug the hotbed T1 cable at the mainboard instead.
-
For 10123, check the temperature on the main screen with the printer cold.
It is normally around 25 °C, close to the room temperature.
Anycubic says this code also shows when the reading is below 10 °C; move the printer somewhere warmer. -
If it still shows, measure the sensor's resistance at room temperature with the printer off.
This needs some electrical knowledge and a multimeter; skip it if you are not comfortable with that.
Anycubic's values at 25 °C: about 100 kΩ, within 15 kΩ for the print head and 10 kΩ for the hotbed.
Outside that range, Anycubic says to replace the print head or the hotbed. -
If the code stays, contact the store you bought the printer from or Anycubic's technical support.
Anycubic asks for a photo of the error code, the model and serial number, and the firmware version.