A5

Daikin Air Conditioner

Severity: Moderate

What it means

Daikin's malfunction code table (Daikin Philippines' Error Code Search Tool) lists A5 for its Room Air (home split) units.
In cooling it means freeze-up protection control; in heating, high pressure control.
The causes it gives: a clogged indoor air filter and short-circuiting air, or a defective indoor heat exchanger thermistor (temperature sensor).

How to Fix It

  1. Switch the unit off and clean the indoor unit's air filter.

    Your operating manual shows how to take it out.

  2. Make sure nothing blocks the indoor unit's air inlet or outlet.

    Short-circuiting means the air blown out goes straight back into the inlet.

  3. If A5 comes back with a clean filter, contact a Daikin service center.

    The heat exchanger thermistor may need replacing.