F95

Panasonic Air Conditioner

Severity:

What it means

Panasonic's air conditioner error code table lists F95 as outdoor cooling high pressure protection.
Panasonic's service manual for the CU-E12RB4UW and CU-E18RB4UW says it shows when the outdoor coil gets too hot during cooling or soft dry, four times within 20 minutes.
The causes it gives: hot air blown out of the outdoor unit being drawn back in, a defective outdoor fan motor, a defective coil sensor, or a defective outdoor board.

Affected Models

  • Panasonic inverter split air conditioners (details from the CU-E12RB4UW and CU-E18RB4UW service manual)

How to Fix It

  1. Switch the unit off and clear everything within reach of the outdoor unit's inlet and outlet: plants, covers, stored things, or laundry.

  2. Let it cool down, switch it on, and look from outside whether the outdoor fan turns.

    Never reach into the fan.

  3. Contact a qualified service technician and give them the code.

    Panasonic's advice for every code in its table is to note it down and have a technician inspect and repair the unit.