H98

Panasonic Air Conditioner

Severity: Moderate

What it means

Panasonic's air conditioner error code table lists H98 as indoor high-pressure protection.
Panasonic's service manual for the CU-E12RB4UW and CU-E18RB4UW says it is stored when the indoor coil gets very hot in heating, and the unit stops and restarts very often; no alarm shows.
The causes it gives: a clogged air filter or indoor coil, the indoor coil's temperature sensor, or a pipe bent too sharply.
Its table adds a short circuit of air: the unit draws its own warm air back in.

Affected Models

  • Panasonic inverter split air conditioners (details from the CU-E12RB4UW and CU-E18RB4UW service manual)

How to Fix It

  1. Switch the unit off and clean the air filters of the indoor unit.

  2. Make sure curtains or furniture don't send the warm air straight back into the unit.

  3. If it still stops and restarts, contact a qualified service technician.