H98
Panasonic Air Conditioner
Severity: ModerateWhat it means
Panasonic's air conditioner error code table lists H98 as indoor high-pressure protection.
Panasonic's service manual for the CU-E12RB4UW and CU-E18RB4UW says it is stored when the indoor coil gets very hot in heating, and the unit stops and restarts very often; no alarm shows.
The causes it gives: a clogged air filter or indoor coil, the indoor coil's temperature sensor, or a pipe bent too sharply.
Its table adds a short circuit of air: the unit draws its own warm air back in.
Affected Models
- Panasonic inverter split air conditioners (details from the CU-E12RB4UW and CU-E18RB4UW service manual)
How to Fix It
-
Switch the unit off and clean the air filters of the indoor unit.
-
Make sure curtains or furniture don't send the warm air straight back into the unit.
-
If it still stops and restarts, contact a qualified service technician.