Invalid syntax block
Texas Instruments TI-89 Calculator
Severity: MinorWhat it means
590: a Dialog..EndDlog block is empty or has more than one title, or a Custom or Toolbar block isn't complete.
520: the command, such as Item, is invalid outside Custom..EndCustm or ToolBar..EndTbar blocks.
530: the command, such as Title, is invalid outside Dialog, Custom and ToolBar blocks.
540: the command, such as DropDown, is invalid outside a Dialog..EndDlog block.
Affected Models
- Texas Instruments TI-89 and TI-92 Plus
How to Fix It
-
590: give the Dialog one title and at least one element.
Items in Custom must be preceded by a title, and Custom can't contain PIC variables.
Toolbar needs a second argument when no items follow. -
520, 530 and 540: move the command into its block.