E62
Electrolux Dryer
Severity: ModerateWhat Does This Error Mean?
E62 means the safety thermostat has failed or tripped due to overheating. It cuts power to the heater to prevent a fire. Clean the exhaust vent first, then test the thermostat.
Affected Models
- Electrolux Electric Dryer
- Electrolux EDC Series
- Electrolux EW Series
Common Causes
- Faulty safety thermostat that has failed open
- Safety thermostat tripped due to blocked exhaust vent
- Overloaded drum restricting internal airflow
- Restricted exhaust duct causing drum temperature to spike
How to Fix It
-
Clean the exhaust vent and lint filter.
Clear all lint from the filter and the full duct run. A clogged vent causes drum temperatures to rise above safe limits, tripping the safety thermostat.
-
Allow the dryer to cool down completely.
Unplug for 30 minutes before testing. If the thermostat tripped due to a one-time blockage, it may reset after cooling.
-
Test and replace the safety thermostat.
Locate the safety thermostat on the heating element housing or duct (it looks similar to the cycling thermostat but is usually rated at a higher temperature). Test with a multimeter at room temperature — it should have continuity. Replace if open.
When to Call a Professional
If cleaning the vent clears E62 but it returns within a few loads, the thermostat has been weakened by repeated overheating and should be replaced.