F-02
Maytag Dryer
Severity: MinorWhat it means
Maytag's service job aid for its Bravos dryers lists F-02 as a Keypad/User Interface Failure.
The causes it gives are a stuck button, or a user interface that does not match the dryer's control.
Maytag says it only appears in the diagnostic test mode, so it is usually a technician who sees it.
Affected Models
- Maytag Bravos electric dryers MED6300TQ, MED6400TB and MED6400TQ
- Maytag Bravos gas dryers MGD6300TQ, MGD6400TB and MGD6400TQ
How to Fix It
-
Press each button on the control panel once, and check that none stays pressed in.
-
If F-02 comes back, request Maytag service.
The technician tests the buttons and their indicators, then the user interface assembly.