F-26
Maytag Dryer
Severity: ModerateWhat it means
Maytag's service job aid for its Bravos dryers lists F-26 as a Motor Drive System Failure.
Its motor test covers every part on that circuit: the wiring, the thermal fuse, the belt and belt switch, the drive motor and its centrifugal switch, the door switch and the machine control electronics.
So the code points to the circuit, not to one part.
Affected Models
- Maytag Bravos electric dryers MED6300TQ, MED6400TB and MED6400TQ
- Maytag Bravos gas dryers MGD6300TQ, MGD6400TB and MGD6400TQ
How to Fix It
-
Close the door firmly and try to start the cycle again.
The door switch is one of the parts on the motor circuit in Maytag's test.
-
Request Maytag service.
The technician works through the motor circuit with the power off, from the control board to the motor, before replacing anything.