X01TPZ001

Peloton Exercise Bike

Severity: Moderate

What it means

Peloton's support article says that to fix X01TPZ001 on the Bike or Bike+, you inspect the cable connected to the sensor board.
The sensor board is the black bar with cables coming out on the right-hand side of the bike, under the plastic shroud over the flywheel.

How to Fix It

  1. Turn off the touchscreen, power down the bike and unplug it, then unplug the power/data cable from the brake shroud.

  2. Remove the shroud.

    With the 3mm Allen wrench from the bike's toolkit, remove the shoulder bolt at the front of the water bottle holder (hold the captured nut) and pull the holder off.
    Remove the shoulder bolt at the front of the shroud, push the USB-C inlet through from the back, ease the wire out of its slot, and lift the shroud off.

  3. Find the cable between the sensor board and the shroud, where the cable from the handlebars plugs in. Unplug it, plug it back in, and turn the touchscreen on.

    Peloton says to repeat this a few times if the error comes back.

  4. If that does not work, remove the USB-C to Sensor Cable completely and plug the cable from the bottom of the handlebars straight into the sensor bar.

    You may need to lower the handlebars.
    If the error goes away, the USB-C to Sensor Cable is the problem.

  5. If the code does not go away, contact Peloton Member Support and tell them what you have tried.