Low Fuel Level (2680), Extremely Low Fuel Level (2681)

Generac Standby Generator

Severity: Moderate

What it means

These are for diesel generators.
Low Fuel Level (2680), or Low Fuel (20%) on the Evolution controller, is a warning: about 20% of the fuel is left, and the generator keeps running.
Extremely Low Fuel Level (2681), or Low Fuel (10%), is an alarm: less than 10% is left, and the generator shuts down.

Affected Models

  • Generac liquid-cooled standby generators with the Power Zone 410 controller
  • Generac 15 to 50 kW Protector diesel generators with the Evolution controller

How to Fix It

  1. Fill the tank with diesel.

    Stop below 90%: above that the controller warns Diesel High Fuel Level (2682).

  2. Clear the alarm.

    Evolution controller: press OFF, then ENTER.
    Power Zone 410: on the Alarm Screen press STOP, then ENTER.

  3. Set the generator back to AUTO.

Frequently Asked Questions

What is Critical High Fuel Level (2691)?

The fuel is above the level set as the high limit, 95% from the factory, for more than one second.