FL1, FL2
Sundance Hot Tub
Severity: ModerateWhat it means
FL1 flashing means the flow (pressure) switch isn't closed while the pump runs: the filter is dirty, air is trapped, or the switch is faulty.
FL2 flashing means the switch is malfunctioning closed.
With either of them the heater is deactivated.
Affected Models
- Sundance 680 and 780 Series hot tubs
How to Fix It
-
Check the water level, and add water if it is low.
780 Series: above all the jets and below the lowest pillow.
680 Series: one inch (2.5 cm) below the lowest pillow. -
Take the filter cartridge out, and clean or replace it if it is clogged.
-
780 Series: with the cartridge out, hold a garden hose to the filter wall fitting, with a rag as a seal, and run water for 30 seconds to push out trapped air.
-
680 Series: loosen the upper drain screw of jets pump 1 for a few seconds to let the air out, and retighten it with your fingers only.
-
780 Series: if the circulation pump doesn't run, switch the main breaker off and on to restart its priming.
-
Contact your Sundance dealer or a qualified service technician.
If it stays, or if it is FL2, the switch is checked.