FL1, FL2

Sundance Hot Tub

Severity: Moderate

What it means

FL1 flashing means the flow (pressure) switch isn't closed while the pump runs: the filter is dirty, air is trapped, or the switch is faulty.
FL2 flashing means the switch is malfunctioning closed.
With either of them the heater is deactivated.

Affected Models

  • Sundance 680 and 780 Series hot tubs

How to Fix It

  1. Check the water level, and add water if it is low.

    780 Series: above all the jets and below the lowest pillow.
    680 Series: one inch (2.5 cm) below the lowest pillow.

  2. Take the filter cartridge out, and clean or replace it if it is clogged.

  3. 780 Series: with the cartridge out, hold a garden hose to the filter wall fitting, with a rag as a seal, and run water for 30 seconds to push out trapped air.

  4. 680 Series: loosen the upper drain screw of jets pump 1 for a few seconds to let the air out, and retighten it with your fingers only.

  5. 780 Series: if the circulation pump doesn't run, switch the main breaker off and on to restart its priming.

  6. Contact your Sundance dealer or a qualified service technician.

    If it stays, or if it is FL2, the switch is checked.