P4
Daikin Split AC
Severity: ModerateWhat Does This Error Mean?
P4 on a Daikin AC means the radiation fin (heat sink) temperature sensor on the inverter board has faulted — open or short circuit. The inverter cannot monitor its own cooling. The unit shuts down to prevent overheating damage. Sensor or board replacement is needed.
Affected Models
- Daikin FTKF Series
- Daikin FTKG Series
- Daikin ATKF Series
- Daikin FTXM Series
- Daikin Inverter Split AC (all models)
Common Causes
- Failed radiation fin temperature sensor (NTC thermistor)
- Sensor wiring loose at the inverter board connector
- Damaged sensor pins from rough handling during a previous service
- Inverter board fault affecting sensor input
- Moisture ingress at the sensor housing
How to Fix It
-
Power off the AC for 30 minutes.
A long power-off allows the sensor to cool and the inverter to reset. Some P4 events from temporary high temperatures clear after cooling.
-
Clear airflow obstructions at the outdoor unit.
While P4 is a sensor fault, restricted airflow can cause real overheating that damages the sensor over time. Clean the outdoor coil and ensure 30 cm minimum clearance on all sides.
-
Restart and watch.
Restore power and run a short cooling cycle. If P4 clears and the AC works normally, the cause was a transient fault. If P4 returns immediately or after a few minutes, the sensor is faulty.
-
Book Daikin service for sensor replacement.
Sensor parts cost USD 30–60. Labour adds USD 150–250 because the technician must access the outdoor electrical box. Total typical cost USD 200–300 fitted.
-
Confirm board health during service.
Ask the technician to check the inverter board for damage from any previous overheating. P4 sometimes accompanies marginal board damage — fixing both at once avoids a return visit.
When to Call a Professional
P4 requires opening the outdoor electrical compartment to access the sensor. Book Daikin-authorised service — DIY here risks both component damage and electrical hazards.
Frequently Asked Questions
Will P4 damage my Daikin AC?
P4 itself is a protection fault — it shuts down the unit before damage occurs. However ignoring P4 (forcing restart) bypasses the protection and risks real overheating damage. Always resolve P4 properly.
Can I keep using my Daikin AC with P4?
No — P4 prevents starting. The inverter cannot operate safely without temperature monitoring. Wait for service rather than attempting workarounds.