FLAME, FLAME OUT
Camp Chef Pellet Grill
Severity: MinorWhat it means
On older Camp Chef digital controllers (Woodwind, SmokePro SG 24, SmokePro PG24XT), the display shows FLAME when the fire is extinguished. On newer controllers, such as the one on the DLX 24, it shows FLAME OUT when the fire goes out, or falls below a certain temperature and does not come back up.
Camp Chef says this happens more in the winter months, and that damp pellets are a common reason: pellets that crumble easily have moisture in them.
How to Fix It
-
Turn the power off. Camp Chef warns never to restart the grill after the flame has gone out without first cleaning out the burner: too many pellets in it can cause an uncontrolled fire.
-
Check the hopper for pellets, and use dry ones.
-
Pull the burner clean-out lever and remove the cup from the bottom of the grill to see how many pellets are in the burner.
-
Lots of pellets: put the cup back and close the clean-out. Remove the grates, grease tray and heat deflector, and vacuum out the pellets in the bottom of the grill. Restart. If pellets reach the burner cup but do not light, the heating rod (hot rod) may need replacing.
-
Few or no pellets: turn the dial to FEED and see whether pellets drop. If none come, check the auger. You can tell the auger motor is running if the small white fan at its end, under the hopper, turns. If the fan turns but the auger does not, the auger pin has sheared and needs replacing.
-
If that does not solve it, call Camp Chef customer service.