HS, HE
Hayward Pool Heater
Severity: ModerateWhat it means
On Hayward Universal H-Series gas pool heaters (H150FD to H500FD), Hayward's manual lists HS as an excessive water temperature error: the water went over 105°F (40.6°C). The heater shuts down and restarts 2 minutes after the water drops below 105°F.
HE means the water temperature rose too quickly. The heater shuts down and restarts after 2 minutes, but after the third time in one call for heat it stays locked out. Hayward's troubleshooting guide covers both under HS.
How to Fix It
-
Check the set point: the heater's range only goes up to 104°F (40°C).
-
Check that the pool pump is running and the filter is clean. Water moving slowly through the heater may heat up faster than the heater expects.
-
If the code returns with good water flow, call a technician to check the temperature sensors and limit switches.
When to Call a Professional
Hayward's owner's manual says to contact a qualified service company for help with any error code. The parts involved sit inside a gas appliance: only a qualified technician should open the heater.