HS, HE

Hayward Pool Heater

Severity: Moderate

What it means

On Hayward Universal H-Series gas pool heaters (H150FD to H500FD), Hayward's manual lists HS as an excessive water temperature error: the water went over 105°F (40.6°C). The heater shuts down and restarts 2 minutes after the water drops below 105°F.
HE means the water temperature rose too quickly. The heater shuts down and restarts after 2 minutes, but after the third time in one call for heat it stays locked out. Hayward's troubleshooting guide covers both under HS.

How to Fix It

  1. Check the set point: the heater's range only goes up to 104°F (40°C).

  2. Check that the pool pump is running and the filter is clean. Water moving slowly through the heater may heat up faster than the heater expects.

  3. If the code returns with good water flow, call a technician to check the temperature sensors and limit switches.

When to Call a Professional

Hayward's owner's manual says to contact a qualified service company for help with any error code. The parts involved sit inside a gas appliance: only a qualified technician should open the heater.