FAULT- HIGH LIMIT

Jandy Pool Heater

Severity: Critical

What it means

FAULT- HIGH LIMIT on a Jandy JXi or LXi gas heater means the water temperature in the heater has exceeded its internal limit, or a limit switch has a fault.
The 2014 Pro Series JXi manual adds a failed temperature control thermostat as a cause.

Affected Models

  • Jandy JXi gas pool and spa heaters
  • Jandy LXi gas pool and spa heaters

How to Fix It

  1. Make sure the pump is running, the filter is clean and the valves are open. For a temperature rise across the heater that is too high, Jandy's LXi manual says to check the pipe size and the pump capacity, and to look for an obstruction or a closed valve.

  2. The 2020 JXi manual starts with the vent: inspect it for obstructions or blockages. On an indoor heater, check the vent pipe for birds, insects or rodents that could block it.

  3. The rest is for a qualified service technician: checking the high limit switches and their connections, finding the cause of the overheating, and replacing a failed switch.

    Jandy says the heater must be serviced only by a qualified professional service technician: the work involves fuel gas, electricity and safety controls.