P1
Honeywell Portable Air Conditioner
Severity: MinorWhat it means
Honeywell's manual for the HF8CESVWK5 and HF0CESVWK6 lists P1 as the water full alarm.
Condensation collects inside the unit; when the internal tank is full, P1 shows and an alarm beeps for 3 seconds.
The unit won't run until the water is drained.
Honeywell says the tank only needs emptying in humid conditions.
Affected Models
- Honeywell HF8CESVWK5 and HF0CESVWK6 portable air conditioners
How to Fix It
-
Unplug the unit.
-
Put a drain pan under the lower rubber drain plug, and take off the drain plug cap.
The water drains into the pan.
-
When the water has drained, put the cap back on, then plug the unit in and switch it on.
The compressor waits about 4 minutes after a switch-off before it starts again.
-
If P1 keeps coming back in dehumidifier mode, set up continuous draining.
Honeywell recommends it for dehumidifier mode: a hose on the upper drain plug, as shown in your manual.