F01
CyberPower UPS
Severity: ModerateWhat it means
F01 with the FAULT icon on a CyberPower CP1350PFCLCD or CP1500PFCLCD is the Battery Mode or Line Mode Overload fault.
The battery outlets were overloaded, either during a power cut (battery mode) or on mains power (line mode).
CyberPower's manual says to turn the UPS on again.
Affected Models
- CyberPower CP1350PFCLCD and CP1500PFCLCD (PFC Sinewave)
How to Fix It
-
Press the POWER button to turn the UPS off.
-
Unplug some equipment from the battery outlets.
Large devices such as laser printers, paper shredders, copiers and space heaters should not be on the battery outlets at all.
Plug low-priority devices into the surge-only outlets instead. -
Turn the UPS on again.
If F01 comes back with less load, contact CyberPower support.
Frequently Asked Questions
How is F01 different from the OVER LOAD icon?
OVER LOAD is a warning: the icon and the alarm stay on until you unplug enough equipment.
F01 is a fault: the UPS shows FAULT, and you turn it off and on again.