E4A, E4C, E4E
GE Washer
Severity: ModerateWhat it means
GE's 2005 service guide for its front-load washers WBVH6240, WCVH6260 and WHDVH626 gives three codes for the inverter's DC bus voltage, the supply inside the board that runs the motor.
E4A, Under volts: the DC bus voltage is too low.
E4C, Over volts: the DC bus voltage is too high.
E4E, Under volts after start: the minimum voltage never arrives, so the motor doesn't run.
For all three, GE's step is to unplug the washer for 30 seconds and retry, and to replace the inverter if the code comes back.
Affected Models
- GE WBVH6240, WCVH6260 and WHDVH626 front-load washers (service guide 31-9135)
How to Fix It
-
Unplug the washer, wait 30 seconds, plug it back in and try the cycle again.
-
If the code comes back, book a technician to test the inverter.