ECF

A.O. Smith Water Heater

Severity: Moderate

What it means

A.O. Smith's hybrid electric heat pump water heater manuals (ProLine XE and Voltex) list ECF as: the heat pump compressor is starting and stopping frequently.

How to Fix It

  1. Press any button on the display to silence the alarm.

    A.O. Smith says an audible alarm may sound with this code.

  2. Turn off the power at the circuit breaker or fuse box, and clean the air filter.

    The steps are the same as for the SF code.

  3. Check that the room around the heater is big enough.

    The ProLine XE manual says to check the location against the confined space requirements in its installation section.

  4. If ECF stays, have a qualified person check the fan wire connection.

    The ProLine XE manual adds: if the compressor runs but the fan does not, call residential technical support on 1-800-527-1953.