EoF
A.O. Smith Water Heater
Severity: ModerateWhat it means
A.O. Smith's hybrid electric heat pump water heater manuals (ProLine XE and Voltex) list EoF for condensate, the water the heat pump produces.
The ProLine XE manual calls it condensate management.
The Voltex manual lists it as condensate pump failure, on units with the accessory condensate pump.
How to Fix It
-
Press any button on the display to silence the alarm.
A.O. Smith says an audible alarm may sound with this code.
-
Make sure the unit is installed level.
-
Check the primary and secondary condensate drain lines for blockages, and clear them.
A.O. Smith's maintenance section also has the drain pan cleaned: with the power off, loosen the screws holding the top shroud, lift it off, and wipe out any dirt with a damp cloth.
-
If an accessory condensate pump is fitted, check that it is plugged in and has power.
Check the circuit breaker or fuse box, and the GFCI outlet if one is used.
Then check the pump's outlet tube for a blockage. -
With the power off at the breaker, check the control wire connections to the condensate pump.
If the pump does not work properly, repair or replace it.
-
If EoF stays, call A.O. Smith's Technical Assistance Hotline on 1-800-527-1953.