76 / 1D / 1E

Fujitsu Air Conditioner

Severity: Moderate

What it means

On Fujitsu's wired remote controls, 76, 1D and 1E are the 2-way / 3-way valve thermistor error.
A thermistor is a temperature sensor, and these usually sit by the outdoor unit's 2-way and 3-way valves, where the refrigerant pipes connect.
The checklist in Fujitsu General America's service help center: the sensor's plug on the main control board must be fully in (Fujitsu: it snaps when it is).
If it is, the thermistor is measured with an ohm meter and replaced if it reads out of range.
If it reads fine, the main control board most likely needs replacing.

Affected Models

  • Fujitsu air conditioners with a wired remote control (UTY-RNNUM, UTY-RVNUM, UTY-RSNUM, UTY-RNRUZ, UTY-RSRY, UTY-RHRY)

How to Fix It

  1. Call a licensed HVAC technician.
    The checks are on the outdoor unit's control board, with the covers off.