CH61, CH34, P4, P6, P7, P8

LG Air Conditioner

Severity: Moderate

What it means

LG says CH61 appears when the outdoor unit gets too hot during cooling, or the indoor unit gets too hot during heating.
In cooling, hot air builds up around a poorly ventilated outdoor unit; the code stops it to prevent damage or fire.
In heating, poor air intake, often from a dirty filter, overheats the indoor unit.
Some models show P4, P6, P7, P8 or CH34 instead.
The code does not clear by itself.

How to Fix It

  1. If the outdoor unit is on an enclosed balcony, open the ventilation window or screen.

    Hot air that cannot escape flows back into the unit.

  2. Clear anything piled up around the outdoor unit.

  3. If the unit sits lower than the ventilation window, raise it on a stand to line up with the window; if it is far from the window, fit an air guide.

    LG says an air guide lowered the temperature around the outdoor unit by about 6 to 8°C in its tests.

  4. If it happened while heating, clean the indoor unit's air filter.

  5. Reset the air conditioner: unplug it or switch off its circuit breaker, wait about 5 minutes, then restore the power.

  6. If CH61 comes back, have a service technician inspect the unit.