F93
Panasonic Air Conditioner
Severity:What it means
Panasonic's air conditioner error code table lists F93 as abnormal compressor revolution.
Panasonic's service manual for the CU-E12RB4UW and CU-E18RB4UW says it shows when the compressor's rotation fails its check four times within 20 minutes.
The causes it gives: a disconnected compressor terminal, a faulty outdoor board, or a faulty compressor.
Affected Models
- Panasonic inverter split air conditioners (details from the CU-E12RB4UW and CU-E18RB4UW service manual)
How to Fix It
-
Switch the unit off at the breaker for a few minutes and back on once.
-
Contact a qualified service technician and give them the code.
Panasonic's advice for every code in its table is to note it down and have a technician inspect and repair the unit.