H16

Panasonic Air Conditioner

Severity:

What it means

Panasonic's air conditioner error code table lists H16 as an outdoor current transformer (CT) abnormality.
The current transformer measures the current the outdoor unit draws.
Panasonic's service manual for the CU-E12RB4UW and CU-E18RB4UW says it shows when that current stays below its threshold for 3 minutes with the compressor running.
The causes it gives: lack of refrigerant gas, a broken current transformer, or a broken outdoor board.

Affected Models

  • Panasonic inverter split air conditioners (details from the CU-E12RB4UW and CU-E18RB4UW service manual)

How to Fix It

  1. Notice whether the unit still cooled or heated well before the code, and tell the technician.

    Weak cooling before H16 may point to lost refrigerant.

  2. Contact a qualified service technician and give them the code.

    Panasonic's advice for every code in its table is to note it down and have a technician inspect and repair the unit.