E5, E05
GE Dryer
Severity: ModerateWhat it means
E5 always points at the outlet thermistor, but the fault differs by model.
On the Profile DPVH880, E5 means the outlet thermistor is open.
On the DBVH512, DCVH515 and DHDVH52, E05 means the same: an outlet thermistor open circuit.
On the GFDS350, GFDS355, GFDN240 and GFDN245, E5 means the outlet thermistor is shorted.
In GE's 2011 guide, the outlet thermistor measures the air going out, and it sits low at the back of the blower housing.
GE's 2011 guide adds that when a thermistor fails, the dryer logs the code and drops to about half heat, with its backup thermostats in control, so loads take longer.
Affected Models
- GE Profile DPVH880 (service guide 31-9167)
- GE DBVH512, DCVH515 and DHDVH52, which show it with a zero (service guide 31-9136)
- GE GFDS350, GFDS355, GFDN240 and GFDN245 (service guide 31-9209)
How to Fix It
-
Write down the code and the model number from the dryer's rating label.
-
Book a technician to test the thermistor and its wiring.
GE's guides have the thermistor checked and replaced if it has failed.