E6
GE Dryer
Severity: ModerateWhat it means
GE's 2011 service guide for the GFDS350, GFDS355, GFDN240 and GFDN245 lists E6 as outlet thermistor open.
In GE's 2011 guide, the outlet thermistor measures the air going out, and it sits low at the back of the blower housing.
GE's 2011 guide adds that when a thermistor fails, the dryer logs the code and drops to about half heat, with its backup thermostats in control, so loads take longer.
The other GE dryer guides don't use E6: on the Profile DPVH880 and the DBVH512 family, an open outlet thermistor shows as E5 or E05.
Affected Models
- GE GFDS350, GFDS355, GFDN240 and GFDN245 (service guide 31-9209)
How to Fix It
-
Write down the code and the model number from the dryer's rating label.
-
Book a technician to test the thermistor and its wiring.
GE's guides have the thermistor checked and replaced if it has failed.