E4, E04
GE Dryer
Severity: ModerateWhat it means
GE's service guides agree on E4: the inlet thermistor is open, so the control reads no proper temperature from it.
That holds on the Profile DPVH880, on the GFDS350, GFDS355, GFDN240 and GFDN245, and as E04 on the DBVH512, DCVH515 and DHDVH52.
In GE's 2011 guide, the inlet thermistor measures the air coming in, and on electric models it sits on the heater housing.
GE's 2011 guide adds that when a thermistor fails, the dryer logs the code and drops to about half heat, with its backup thermostats in control, so loads take longer.
GE's 2005 guide warns that a code only shows which part to test: the control can set a false error, so the part is checked before it's replaced.
Affected Models
- GE Profile DPVH880 (service guide 31-9167)
- GE GFDS350, GFDS355, GFDN240 and GFDN245 (service guide 31-9209)
- GE DBVH512, DCVH515 and DHDVH52, which show it with a zero (service guide 31-9136)
How to Fix It
-
Write down the code and the model number from the dryer's rating label.
-
Book a technician to test the thermistor and its wiring.
GE's guides have the thermistor checked and replaced if it has failed.