F-24, F-25

Maytag Dryer

Severity: Moderate

What it means

Maytag's service job aid for its Bravos dryers lists F-24 as Inlet Thermistor Open and F-25 as Inlet Thermistor Shorted.
The inlet thermistor reads the temperature of the air going into the drum, and it is part of one assembly with the high limit thermostat.
Only the electric models list these codes.
Maytag says they only appear in the diagnostic test mode.

Affected Models

  • Maytag Bravos electric dryers MED6300TQ, MED6400TB and MED6400TQ (the gas models' list has no F-24 or F-25)

How to Fix It

  1. Request Maytag service.

    The technician checks the wire connections at the control and at the thermistor, then measures the thermistor.
    Because the thermistor and the high limit thermostat are one assembly, a failed thermistor usually means replacing the whole assembly.