What it means

Depending on the grill, it shows as Low Temp Error, Error: 0002 Low Temp Error, or ER02. If the grill is paired with the Traeger app, the app sends a notification too.
Traeger says the grill gives this error when it stays below 120°F (48°C) for more than 10 minutes. It then tries to relight, and if that fails it starts its shutdown cycle. Causes Traeger lists: poor pellets, no pellets in the firepot or pellets tunneling in the hopper, a wrong startup, outdated firmware, poor maintenance and faulty parts.

How to Fix It

  1. Traeger says the most common fix is a correct restart. Turn the grill on, make sure the lid is closed, set the temperature, then press Ignite.

  2. Make sure the grill has the latest firmware. Traeger lists current versions at traeger.com/status, and a grill left on WiFi should update itself.

  3. Check the pellets: good pellets are shiny and snap when broken. Take a sample from the bottom of the hopper, and vacuum out sawdust there, since sawdust does not burn.

  4. Look in the firepot. No pellets points to a gap in the auger after running out, clumped pellets or an auger jam. Too many pellets means the fire was smothered, for example after a wrong shutdown last time or a hot rod that does not heat.

  5. Clean the grill: Traeger recommends cleaning at least every 20 hours of cooking, because ash in the firepot makes it harder to light the pellets.

  6. With the grates, drip tray and heat baffle out, ignite the grill and check the parts: the auger should turn and drop pellets, the induction fan should hum, and you should feel heat from the hot rod over the firepot.