ER02, Error 0002
Traeger Pellet Grill
Severity: MinorWhat it means
Depending on the grill, it shows as Low Temp Error, Error: 0002 Low Temp Error, or ER02. If the grill is paired with the Traeger app, the app sends a notification too.
Traeger says the grill gives this error when it stays below 120°F (48°C) for more than 10 minutes. It then tries to relight, and if that fails it starts its shutdown cycle. Causes Traeger lists: poor pellets, no pellets in the firepot or pellets tunneling in the hopper, a wrong startup, outdated firmware, poor maintenance and faulty parts.
How to Fix It
-
Traeger says the most common fix is a correct restart. Turn the grill on, make sure the lid is closed, set the temperature, then press Ignite.
-
Make sure the grill has the latest firmware. Traeger lists current versions at traeger.com/status, and a grill left on WiFi should update itself.
-
Check the pellets: good pellets are shiny and snap when broken. Take a sample from the bottom of the hopper, and vacuum out sawdust there, since sawdust does not burn.
-
Look in the firepot. No pellets points to a gap in the auger after running out, clumped pellets or an auger jam. Too many pellets means the fire was smothered, for example after a wrong shutdown last time or a hot rod that does not heat.
-
Clean the grill: Traeger recommends cleaning at least every 20 hours of cooking, because ash in the firepot makes it harder to light the pellets.
-
With the grates, drip tray and heat baffle out, ignite the grill and check the parts: the auger should turn and drop pellets, the induction fan should hum, and you should feel heat from the hot rod over the firepot.