ER07, Error 0007, Failed to Ignite

Traeger Pellet Grill

Severity: Minor

What it means

Traeger says the grill entered ignition but did not get a flame going: it watches for the temperature to rise during startup, and if that does not happen in time, it gives this error and shuts down.
It shows as Failed to Ignite on D2 WiFIRE grills, Error: 0007 Grill Failed to Ignite on touchscreen grills (Timberline, Ironwood), ER 07 on Woodridge and Er07 on Westwood grills. Traeger's causes: pellet trouble (empty or overfull firepot, an ash puck, tunneling, poor pellets or sawdust), the lid open at startup, a hot rod problem, or a tripped outlet or breaker.

How to Fix It

  1. Turn off and unplug the grill, and let it cool: the hot rod stays hot after a shutdown.

  2. Keep the lid closed during preheat from now on. Traeger says the grill needs it to light.

  3. Clean out ash and sawdust from the firepot and barrel, and make sure no foil or liner sticks out past the drip tray.

  4. Check the pellets: good pellets are shiny and snap when broken. Take a sample from the bottom of the hopper, and vacuum out sawdust there, since sawdust does not burn.

  5. Check the hot rod: with the grates, drip tray and heat baffle out, its tip should be clean and stick out 1/8 to 1/4 inch (4 to 6 mm). Ignite and hold your hand over the firepot: you should feel heat.

  6. No heat: unplug the grill, take the controller off, and disconnect and reconnect each plug on its back. If the hot rod still does not heat, it needs replacing.

Frequently Asked Questions

My outlet or breaker tripped too. Why?

Traeger says a failing ignitor can trip a GFCI outlet or breaker, often because ash in the firepot touches the ignitor. Clean the firepot regularly. If the GFCI keeps tripping, contact Traeger Support before carrying on.