ER10, Error 0010, Ignitor Not Detected
Traeger Pellet Grill
Severity: ModerateWhat it means
Traeger says the controller is not detecting the expected electrical current from the ignitor, the part that lights the pellets. The grill shuts down and will not start a new cook until it is dealt with.
It shows as Error: 0010 Ignitor Not Detected on touchscreen WiFIRE grills (Timberline, Ironwood) and ER 10 on Woodridge grills.
How to Fix It
-
Let the grill cool fully first: the ignitor stays hot after a shutdown.
-
Touchscreen grills: Traeger says Error 0010 comes from firmware older than v.01.04.00, and updating, the first step, usually fixes it. Update, turn the grill off and on, and start a cook. If the ignitor still has trouble, the grill will show a more specific error, such as Error 0007 or Error 0002.
-
Woodridge grills: take out the grates, drip tray and heat baffle, ignite, and check for heat over the firepot or smoking pellets.
-
No heat on a Woodridge: unplug the grill, remove the auger box panel (10 screws: 2 at each end, 3 along each side), and disconnect and reseat the ignitor plug on the motherboard. Try again.
-
If the pellets still do not smoke, replace the ignitor. If a new ignitor does not help, contact Traeger Customer Support.