Error 0025 Sensor Disconnected
Traeger Pellet Grill
Severity: MinorWhat it means
On touchscreen Timberline and Ironwood grills, Error 0025 Sensor Disconnected means the grill cannot communicate with the lid sensor, so it cannot tell whether the lid is open or closed. The current cook carries on, but at reduced performance.
How to Fix It
-
Make sure the grill has the latest firmware. Traeger lists current versions at traeger.com/status, and a grill left on WiFi should update itself.
-
Run a self-test on the controller: Menu > Maintenance & Care > Self-Test. It takes about 10 seconds.
-
If the lid sensor test fails, the wiring needs checking.
-
To get at the wiring, the hopper service panel on the right side of the hopper comes off (6 screws: 2 on top of the panel, 2 below the hopper side rail, 2 at the bottom). Traeger says grills made before June 2023 (the second set of digits in the serial number lower than 2306) need a manual impact driver so the screws do not strip; if you do not have one, contact Traeger Support.
-
Unplug the grill. Remove the smart combustion cover, make sure every connector on the motherboard is fully in, and check that no wires inside the hopper are pinched, cut or damaged.
-
Run the self-test again. If the lid sensor test still fails, contact Traeger Customer Support.
Frequently Asked Questions
I replaced the lid sensor and the error is still there. Why?
Traeger says to make sure the QR code sticker was removed from the new sensor before it was installed.