Error 0028, ER28, Pellet Sensor Disconnected
Traeger Pellet Grill
Severity: MinorWhat it means
The grill does not detect its pellet sensor, the part that measures the pellets left in the hopper. Touchscreen Timberline and Ironwood grills show Error 0028 Sensor Disconnected. Woodridge Pro and Woodridge Elite grills show ER28, with Pellet Sensor Disconnected in the Traeger app. The grill carries on cooking.
Traeger says the cause is a loose or unplugged connection, or damaged wiring. On new Woodridge grills, ER28 usually means old firmware: it appears with version 02.03.00 and lower.
How to Fix It
-
Make sure the grill has the latest firmware. Traeger lists current versions at traeger.com/status, and a grill left on WiFi should update itself.
-
Touchscreen grills: unplug the grill and take off the hopper service panel on the right side of the hopper (Traeger says grills made before June 2023 need a manual impact driver for its screws), then the smart combustion cover. Disconnect and reconnect all connectors, make sure the pellet sensor cable is secure, and check for pinched or damaged wires (Traeger Customer Support sends new ones).
-
Then run Menu > Maintenance & Care > Self-Test. If the pellet sensor passes, you are done.
-
Woodridge grills on firmware 02.04.00 or later: turn off and unplug the grill. On the Woodridge Elite, take off the filler panel below the controller (4 screws). Open the hopper lid, remove the 2 screws of the controller trim at the top and the 2 at the bottom, and lift the controller and trim out together.
-
Find the connection between the pellet sensor cable and the controller cable. Disconnect it, rub the contacts with a dry cloth or a dry Magic Eraser to remove tarnish, and plug it back in firmly. Put everything back and turn the grill on.
-
If the error comes back, contact Traeger Customer Support, which can replace the sensor if needed.