Pellet Sensor Calibration Error
Traeger Pellet Grill
Severity: MinorWhat it means
On D2 WiFIRE grills, calibrating the pellet sensor can now and then end with "Pellet Sensor Calibration Error. Press OK to start over". It shows only on the controller, not in the app, and it does not stop you using the grill.
How to Fix It
-
Turn off and unplug the grill. Wipe the pellet sensor's lens with a clean cloth: sawdust builds up on it, though not enough to need taking anything apart.
-
Turn the grill on and calibrate again.
-
Check that the firmware is up to date. If it is not, update it and try once more.
-
Still failing: turn the grill off and remove the controller (4 screws). Traeger says the grill must be off whenever the sensor is unplugged and plugged back in, or it will not work until rebooted.
-
Unplug the black pellet sensor plug on the back of the controller, rub the contacts with a dry cloth or a dry Magic Eraser to remove tarnish, and plug it back in fully. Follow the black wire to the white connector and make sure it is secure.
-
Turn the grill on and calibrate. If the error continues, replace the pellet sensor or contact Traeger Customer Support.