FLo, PS

Hayward Pool Heat Pump

Severity: Moderate

What it means

FLo or PS means the heat pump's water pressure switch is open. Hayward's Summit and HeatPro heat pumps show some codes differently: where two are given, the first is the Summit display and the second the HeatPro display.
Hayward says water pressure switches sometimes fail, but most FLo and PS errors are water flow problems: an open bypass valve, a pump timer in its off cycle, a pump that is off, or a dirty filter.

How to Fix It

  1. Check that the pool pump is running, and clean or backwash the filter. Make sure all the valves to the heat pump are open and any bypass valve is closed.

  2. Check that the filter is not in its backwash position, and that the pool pump is getting enough water.

  3. Turn off fountains, automatic cleaners and other equipment that takes water from the same pump.

  4. If the water flow is good and the code stays, the water pressure switch may need adjusting or replacing. That is a job for a service technician: Hayward's guide has them test the switch with a meter first.

Frequently Asked Questions

My newer HeatPro shows E03. Is that a flow error?

Yes. On newer HeatPro models such as the HP31005T, E03 means no water, or very little, in the water system. Hayward's fix is to check the water flow and the pump.