ERR IGN

Pentair Pool Heater

Severity: Moderate

What it means

ERR IGN means the ignition control module was not able to ignite the heater.
The heater stays locked out until you press the HEATER OFF button, which clears the error.

How to Fix It

  1. Check that the gas supply to the heater is turned on, including the outside manual shut-off valve. If the heater runs on propane, check the tank too.

  2. On a first start, or after the heater has been off a long time, air in the gas line can stop the burner lighting. Pentair's start-up steps say to press OFF, wait five minutes and turn the heater on again, repeating until the air has cleared.

  3. If ERR IGN keeps coming back, leave the heater off and call a qualified service technician. Pentair's chart has them check the gas flow and pressure at the heater, the hot surface igniter, the gas valve, the ignition control module and the control board.

When to Call a Professional

If you smell gas, do not try to light the heater or touch electrical switches. Leave, and call your gas supplier from a neighbor's phone (or the fire department if you cannot reach them).