ERR SFS
Pentair Pool Heater
Severity: CriticalWhat it means
ERR SFS means excessive stack flue temperature: the stack flue sensor found the exhaust gas too hot. The limit is 480°F (249°C) on MasterTemp and Sta-Rite SR heaters, and 170°F (77°C) on the ETi 250.
The front panel buttons stop working. To reset the heater, switch its power off and on again.
How to Fix It
-
Pentair's manual says not to run the heater while this code shows: turn it off and have a qualified service technician check the system. Low water flow is one of the causes Pentair lists, so check the pump and filter too.
To turn the heater off fully, Pentair's steps are: press OFF on the control panel, switch off all electric power to the heater, then close the outside manual gas shut-off valve.
-
Pentair's chart splits ERR SFS in two. If the heater runs but the exhaust climbs to 450-500°F within 3 to 5 minutes, the technician checks the heat exchanger coil for leaks, scale, soot or low water flow, and the thermal regulator.
-
If the heater only starts after several tries, or not at all, they check the gas pressure and supply first, then the stack flue sensor, its wiring and its connectors.