ERR AGS
Pentair Pool Heater
Severity: CriticalWhat it means
ERR AGS means the automatic gas shutoff switch has opened.
On MasterTemp and Sta-Rite SR heaters, it opens when the water after its second pass through the heat exchanger is hotter than 140°F (60°C). On the ETi 250, it opens when the outlet water goes above 150°F (65.5°C).
The front panel buttons stop working. Pentair's table says to reset the heater by switching its power off and on again.
How to Fix It
-
Do not keep resetting the heater. Pentair's manual says not to run the heater while this code shows: turn it off and have a qualified service technician check the system.
To turn the heater off fully, Pentair's steps are: press OFF on the control panel, switch off all electric power to the heater, then close the outside manual gas shut-off valve.
-
Meanwhile, check that the pump is running, the filter is clean and the valves to the heater are open. Water flow is the first thing on Pentair's chart for this code.
-
The technician works through the same chart as for ERR HLS: water flow and inlet temperature, the pressure switch setting, the water temperature sensor and control board, then the AGS switch itself. If the fault comes back, they check the bypass valve, the thermal governor and the heat exchanger.