ERR PS
Pentair Pool Heater
Severity: ModerateWhat it means
ERR PS on Pentair MasterTemp, Sta-Rite SR and ETi 250 gas heaters means the water pressure switch is open. Pentair's code table gives the cause as no water flow through the heater.
The burner will not fire while the switch is open. As soon as the water flow is back, the error clears and the heater carries on normally.
How to Fix It
-
Check that the pool pump is running and primed, and that the valves to the heater are open.
-
Clean the filter and the skimmer baskets. Pentair says ERR PS with the pump running usually means they need cleaning, and some filters need backwashing.
-
Pentair gives a minimum flow for each MasterTemp size: 20 gallons (76 litres) a minute for the 175 and 200, 25 (95) for the 250, 30 (114) for the 300 and 40 (151) for the 400. A pump on a low speed setting may not reach it.
-
If ERR PS stays after the filter and skimmers are clean, have a qualified service technician check the system. The water pressure switch is factory set for a heater at deck level; the technician adjusts or replaces it. A heater more than 5 feet (1.5 m) above or 4 feet (1.2 m) below the deck needs a flow switch instead.
Frequently Asked Questions
Can the pressure switch just be turned down?
Not by guesswork. Pentair warns never to bypass the water pressure switch. A wrong setting can let the heater run with no water flow, which may severely damage it and voids the warranty. Leave the adjustment to a technician.