ERR TF, ERR FT
Pentair Pool Heater
Severity: CriticalWhat it means
ERR TF on a Pentair ETi 250 high efficiency heater means a thermal fuse is open. Pentair's manual writes it ERR TF in the text and ERR FT in its code table.
The heater has two thermal fuses in series: one for the temperature of the heat exchanger coils, the other for the flue gas leaving the heat exchanger. A fuse opens the circuit when its limit is exceeded.
How to Fix It
-
Turn the heater off and have a qualified service technician check it. Pentair has the fuse replaced, not reset, once the cause is known.
To turn the heater off fully: press OFF, switch off all electric power to the heater, then close the outside manual gas shut-off valve.
-
Pentair's chart has the technician check the stack flue temperature first. If the flue runs too hot, the heat exchanger needs servicing, and the stack flue sensor may need replacing along with the fuse. If the temperature is normal, the thermal fuse is replaced.