Blocked System, Suction Blockage

Pentair Pool Pump

Severity: Moderate

What it means

On IntelliFlo VS+SVRS and VF pumps, this alarm means the pump has detected a blocked suction line. SVRS stands for Safety Vacuum Release System.
When something fully blocks the suction, the pump shuts off immediately, within one second. It also shuts off after a few seconds of dead heading (pumping against a closed line) with the same alarm.
On the VS+SVRS, the alarm resets by itself after two minutes and the pump ramps back up to speed slowly.

How to Fix It

  1. This is a safety feature against suction entrapment. Check that nothing, and nobody, is caught on a drain or suction outlet.

  2. Clear what is blocking the suction, such as a closed valve, a clogged skimmer or strainer basket, or debris over a drain cover.

  3. Pentair says the SVRS feature is switched off while the pump is priming, and that it should be tested on every new installation. If the alarm keeps coming back with clear suction lines, have a pool technician check the system.