120, 121, 123
Jandy Salt Chlorinator
Severity: ModerateWhat it means
Jandy's service codes 120, 121 and 123 all mean the current reaching the electrolytic cell is low.
120 is low current in the forward direction, 121 low current in the reverse direction, and 123 extremely low current.
The SERVICE indicator on the AquaPure display lights with the code, which shows as a 3-digit number. Jandy's manual says the code repeats twice a minute, and the unit beeps once an hour for the first code.
Affected Models
- Jandy AquaPure salt water chlorinators, including the AquaPure 1400
- Jandy PureLink
How to Fix It
-
Check the salt level. Low salt is the first cause on Jandy's list for the SERVICE indicator, and below 2.0 gpl the unit shows code 144.
-
Turn the pump off, release the filter pressure, remove the cell and look between the plates. Flush scale or debris out with a strong jet from a garden hose, and acid wash only if that fails (the 125 page has Jandy's acid wash steps). For 123, Jandy says the cell may need cleaning or replacing.
-
Check the DC power cord at the cell. It must be properly connected, with no dirt or corrosion on its contacts or on the cell's studs.
-
If the cell is clean, the salt is right and the cord is sound, contact a pool professional.
Codes 126 and 127 are the same low current with the supply voltage below 100/200 VAC. Jandy says to contact a pool professional for those.