NO FLOW

Jandy Salt Chlorinator

Severity: Moderate

What it means

NO FLOW on a Jandy AquaPure display means the flow/temp/salinity sensor in the cell's plumbing does not detect water flowing past it. The cell is turned off, so no chlorine is made.
The AquaPure only makes chlorine while the pump runs. The problem to fix is a NO FLOW that stays on while the pump is running.

Affected Models

  • Jandy AquaPure salt water chlorinators, including the AquaPure 1400
  • Jandy PureLink

How to Fix It

  1. Check that the pump is running and has not lost its prime, and that the strainer baskets are not clogged.

  2. Check that every valve is set so water flows through the cell.

  3. Clean the filter.

  4. Turn the pump off, release the filter pressure and remove the cell. Clear any debris lodged between the plates, and clean the cell if it needs it.

  5. Check the flow/temp/salinity sensor. It must be installed the way Jandy's installation figure shows, plugged in at the power center, and its elements must be clean: not covered with PVC glue, tape or debris. Remove and clean it if needed.

    The sensor plugs into the circuit board inside the control/power center. Turn the power off before you open it, and leave it to a pool professional if you are not comfortable working there. After plugging the sensor in, Jandy says to switch the power off and on again.

  6. If none of that clears it, the sensor may be faulty. Contact a pool professional.