175

Jandy Salt Chlorinator

Severity: Moderate

What it means

Service code 175 on a Jandy AquaPure means a flow sensor air lock condition, or very low salinity.
Level 2 code 182 also brings it up: the salinity sensor sees less than 0.2 gpl of salt, either because there is no salt in the pool or because the sensor is air locked.

Affected Models

  • Jandy AquaPure salt water chlorinators, including the AquaPure 1400
  • Jandy PureLink

How to Fix It

  1. Test the salt with a Myron L meter calibrated for NaCl, or with test strips. If it is low, add salt: Jandy recommends 3.0 to 3.5 gpl.

    Set CHLORINE PRODUCTION to 00% before you add salt. Jandy warns that running the unit above 00% without enough salt damages the cell. The 144 page has Jandy's salt steps.

  2. If the salt is fine, check how the flow/temp/salinity sensor is installed. An air lock means air is trapped at the sensor, so it cannot read the water.

    If the cell or sensor was moved or replaced recently, ask the installer or a pool professional to check it against the installation figure in Jandy's manual.