Lo
Jandy Salt Chlorinator
Severity: MinorWhat it means
Lo on a Jandy AquaPure display is the low temperature cutoff: the pool water is below 50°F (10°C), and the AquaPure has stopped making chlorine.
Jandy lists it with the unit's letter codes, which report a condition rather than a fault.
Affected Models
- Jandy AquaPure salt water chlorinators, including the AquaPure 1400
- Jandy PureLink
How to Fix It
-
Keep testing the free chlorine while the cutoff is on, since the AquaPure is not making any. Jandy recommends 1 to 3 ppm.
-
Jandy notes that very cold water can shorten the cell's life if the chlorinator runs 24 hours a day through winter. It may be necessary to run it at a very low production rate (10 to 20%) or turn it off; the winterizing section of the manual covers this.
Frequently Asked Questions
What do EC, bo, HH, JA and Jb mean on an AquaPure?
They are the other letter codes in Jandy's table.
EC: an ORP unit or other external controller has shut off chlorine production.
bo: Boost, the unit runs at 100% production for 24 hours of run time.
HH: the salinity reading is above the maximum range, so the salt is too high.
JA: an AquaLink RS is controlling the AquaPure and its output percentage.
Jb: an AquaLink RS is controlling the AquaPure and Boost is on.