Check Cell
Jandy Salt Chlorinator
Severity: ModerateWhat it means
Check Cell on a Jandy Pro Series TruClear display has two meanings in Jandy's table, and both stop the chlorine output.
Cell overload: the unit detects a short circuit or overload in the cell. Output is off.
Cell open circuit: the cell is disconnected or its circuit is open. Output is off, and the unit retries every 30 seconds.
Affected Models
- Jandy Pro Series TruClear salt chlorine generator
How to Fix It
-
Turn the power to the power pack off at the circuit breaker first. Then check that the cell's cable is firmly connected to the power pack.
-
Turn the pump off, open the air relief valve on the filter to release the pressure, and remove the cell. Look between the plates.
Jandy's fix for metal debris caught between the plates is a garden hose under moderate pressure. If the plates are loose and touching, the cell needs replacing.
-
Test the salt level. Jandy recommends 3,000 to 3,500 ppm, and salt well above that may also overload the cell. Too much salt only comes down by partly draining the pool and refilling with fresh water.
-
If Check Cell stays after that, contact a pool professional.