Lo Temp/Lo Salt
Jandy Salt Chlorinator
Severity: ModerateWhat it means
Lo Temp/Lo Salt on a Jandy Pro Series TruClear means the unit detects low water conductivity. Cold water, low salt or both can cause it. Chlorine output stays on.
Jandy's troubleshooting table writes it Lo Tmp/Lo Salt. The causes there: salt well below 2,500 ppm, depending on the water temperature; cold water (35 to 65°F, 2 to 18°C) together with lower salt (1,500 to 2,000 ppm); calcium buildup in the cell; or a cell at the end of its life.
Affected Models
- Jandy Pro Series TruClear salt chlorine generator
How to Fix It
-
Test the salt with salinity test strips, a TDS/salinity meter or another reliable method. Between 3,000 and 3,500 ppm, Jandy says no action is needed.
-
Below 2,500 ppm, add salt to reach 3,000 to 3,500 ppm, using the salt table in the TruClear manual. Be conservative: it is easier to add more later than to dilute the pool if there is too much.
The TruClear reads the salinity 5 minutes after it starts and every 5 minutes after that. The salt warning stays on until the level is back to about 3,000 ppm. Jandy notes that salt above 4,500 ppm may cause corrosion damage.
-
If the salt is fine, check the cell for calcium. Turn the power to the power pack off at the circuit breaker first. Close any valves needed to stop water loss, open the filter's air relief valve and remove the cell, then hold the plates up to a light. If light barely shows through, the cell needs cleaning.
-
To clean it, wear glasses and gloves and mix one part muriatic acid into ten parts water in a small bucket: acid into water, never water into acid. Submerge the cell.
Foaming means scale is dissolving; it usually stops after 5 to 10 minutes. If there is no foaming, the cell does not need cleaning. Never leave it in for more than 30 minutes, and never scrape the plates with a screwdriver or other metal object. Rinse the cell with tap water, check it again and refit it.
-
If the salt is right and the cell is clean, the cell may be at the end of its life. Jandy's fix then is a new cell.
Frequently Asked Questions
Should the TruClear run in cold water?
Jandy does not recommend running it below 55°F (13°C): cold water can dramatically shorten the cell's life.
For long spells of cold water, Jandy says to turn the unit off and use a chlorine floater or erosion feeder with a few tablets until the water warms up.