LO BAT

Honeywell Security Alarm Panel

Severity: Minor

What it means

Fixed-word keypads show BAT. Alpha keypads show LO BAT, or SYSTEM LO BAT.
With a zone number, and the keypad beeping once a minute, the battery in that wireless sensor is low. Zone 00 means a wireless keypad.
With no zone number, the panel's main standby battery is weak.

Affected Models

  • Honeywell VISTA alarm panels, such as the VISTA-10P

How to Fix It

  1. Note the zone number shown, if there is one.

  2. Replace the battery in that wireless sensor.

    Some Honeywell sensors use a long-life battery that cannot be replaced, so the whole sensor is replaced. Honeywell names the 5802 and 5802CP.

  3. If there is no zone number, the panel's standby battery is weak. Call your alarm company to replace it.

Frequently Asked Questions

What happens if I leave it?

Honeywell says that if a sensor's battery is not replaced within 30 days, a CHECK display may appear for that zone.